Using the PIV System Measuring the Flow Pattern of Enlargement Flow in an Open Type Suction Channel of the Pump

G. J. Cao,S. H. Liu,Y. L. Wu,J. Chen
DOI: https://doi.org/10.1088/1755-1315/15/6/062050
2007-01-01
Journal of Engineering Thermophysics
Abstract:The vortex of the open suction channel may cause the vibration, cavitations and performance decreasing of the pump. In this paper, we have made the sudden enlargement profile in the open suction channel of the pump; the flow pattern had been measured by PIV system. The experiment shows that when the fluid flows through the sudden enlargement, the flow area can be divided into three parts: one part is the main flow zone, one part is the backflow zone, and the other part is called mix zone or inter-zone between the two parts. The velocity along the flow direction is larger in the main flow zone; the magnitude in the backflow zone is smaller. The velocity fluctuation at the inter-zone is larger than that at the other two zones, and a bigger velocity deviation band is formed there.