Abstract:By regulating aeration system, anoxic and aerobic areas can coexist in the micro-pressurized fluidized hybrid biological reactor (MP-FHBR). Using the characteristic and the mixed organism of activated sludge and suspended biofilm coexisting in the MP-FHBR, study was conducted for simulataneous nitrogen removal. The experimental results showed that, nitrogen can be effectively simulataneous removal under the condition of anoxic-aerobic in the MP-FHBR. Under the conditions of this experiment, removal rates of TN and COD reached 77.5% and 98.3% respectively. Reducing the DO concentration to form completely anoxic environment within the reactor have no significant influence on TN removal effect of MP-FHBR, but it reduce the COD removal rate of the system. Improving the DO concentration to form completely aerobic environment within the reactor, TN removal effect of MP-FHBR decreased significantly. With the increasing of COD/TN, the TN removal efficiency was increased. TN removal efficiency was increased from 58.4% to 78.8%, when COD/TN was increased from 2 to 10, further increasing COD/TN, TN removal effect was not significantly increased. With the increase of MLSS, the TN removal efficiency was increased, leading to a more apparent denitrification efficiency of MP-FHBR.