Study on SVPWM method based on 60° coordinate system for three-level inverter
Xiao-ou CHEN,Chun-yu XU,Feng-ming WANG
DOI: https://doi.org/10.3969/j.issn.1003-3076.2017.02.007
2017-01-01
Abstract:For the neutral point clamped three-level inverter,a new method for SVPWM based on 60 ° coordinate system can effectively avoid the shortcomings of complex algorithm,and the large amount of calculation which exist in space vector pulse width modulation (SVPWM) method in α-β coordinate system.In this paper,following measures are put forward,namely,60° coordinate system is adopted to improve the control algorithm,g-h coordinate system is established,the relationship between the reference vectors and space coordinates is analyzed,the algorithm of per-unit transformation of the basic voltage vector is proposed,the judgment of sectors is simplified,and acting time of the voltage vectors in sector Ⅰ is calculated.The rotation module is established,and reference voltage vectors in other sectors are rotated to sector Ⅰ,acting time of the voltage vectors is obtained directly,so the operation process is simplified and a lot of trigonometric function calculations are avoided.Based on the Matlab simulation model and experiment,the reliability of the improvement measures is verified,and the response speed of the system becomes quicker.