Utility of single-shot compressed sensing cardiac magnetic resonance cine imaging for assessment of biventricular function in free-breathing and arrhythmic pediatric patients

Qing Zou,Hua-Yan Xu,Chuan Fu,Xiao-Yue Zhou,Rong Xu,Meng-Xi Yang,Zhi-Gang Yang,Ying-Kun Guo,Hua-yan Xu,Xiao-yue Zhou,Meng-xi Yang,Zhi-gang Yang,Ying-kun Guo
DOI: https://doi.org/10.1016/j.ijcard.2021.06.043
IF: 4.039
2021-09-01
International Journal of Cardiology
Abstract:<h3 class="u-h4 u-margin-m-top u-margin-xs-bottom">Background</h3><p>This study aimed to explore the feasibility and accuracy of single-shot compressed-sensing (CS) cardiac magnetic resonance cine technology for the assessment of biventricular function and morphology in free-breathing (FB) pediatrics, especially those with arrhythmia.</p><h3 class="u-h4 u-margin-m-top u-margin-xs-bottom">Methods</h3><p>Seventy consecutive pediatric participants (6.27 ± 3.8 years, range:0.5–14 years) were enrolled between August 2019 and July 2020. Single-shot CS and conventional balanced steady-state free-precession (bSSFP) cine were obtained. The total scanning time, image quality and biventricular function parameters were compared for both sequences.</p><h3 class="u-h4 u-margin-m-top u-margin-xs-bottom">Results</h3><p>Single-shot CS cine had shorter acquisition time compared with the conventional bSSFP cine (all <em><em>P</em></em> &lt; 0.001). The single-shot CS cine also had fewer artifacts than conventional bSSFP cine (breath-hold (BH): 4.6 ± 0.6 vs. 4.3 ± 0.6; FB without ongoing arrhythmia: 4.5 ± 0.6 vs. 3.6 ± 0.9; FB with ongoing arrhythmia: 4.7 ± 0.5 vs. 2.6 ± 1.1; all <em><em>P</em></em> &lt; 0.05). No statistical difference of left ventricular parameters and right ventricular end-systolic volume/ejection fraction were found between the single-shot CS and conventional bSSFP cine in both BH and FB without ongoing arrhythmia group. There was an excellent correlation (<em><em>R</em></em><sup>2</sup> = 0.60–0.98, all <em><em>P</em></em> &lt; 0.001) and good intra-(range: <em><em>R</em></em><sup>2</sup> = 0.57–0.99, <em><em>P</em></em> &lt; 0.001)/inter-observer agreements (range: <em><em>R</em></em><sup>2</sup> = 0.76–1, <em><em>P</em></em> &lt; 0.001) for single-shot CS cine images in terms of biventricular function parameters.</p><h3 class="u-h4 u-margin-m-top u-margin-xs-bottom">Conclusions</h3><p>The single-shot CS cine can significantly reduce the image acquisition time, offering reliable quantification of biventricular function in free breathing condition for arrhythmic patients.</p>
cardiac & cardiovascular systems
What problem does this paper attempt to address?