A Study of Hydrodynamic Characteristics of an Underwater On-line Condenser-cleaning Robot

陈宁,万翼,彭伟,吴楠楠
DOI: https://doi.org/10.3969/j.issn.1671-8909.2008.07.008
2008-01-01
Abstract:By using a numerical simulation and related tests,a study has been performed of the hydrodynamic characteristics of an on-line-cleaning industrial robot destined for the condenser of a 300 MW steam turbine,which is now still under development.It is noted that the robot under discussion will not affect the normal operation of the condenser after being put into the return water chamber of the condenser,but there exist three unfavorable working zones for the operation of the robot.The first zone is located in a region above the condenser partition grate within a height five times of the tube diameter of the partition grate.The second unfavorable zone is situated at the robot's second-stage arm level in a region where the third-stage and second-stage arm form an included angle of 3 to 7 degrees.The third unfavorable zone is in a working region where the manipulator of the robot is pointing to the corner of the condenser.When the robot is working in the above-said unfavorable zones,the vibration of the robot manipulator will increase considerably,thus affecting the fixed location operation.Finally,the authors have conducted an exploratory study of the methods for coping with the above unfavorable zones and noted that an additional installation of a self-adaptive rotary flow-straightening hood on the arm rod of the robot is one of the effective measures.
What problem does this paper attempt to address?