CNN-Assisted Adaptive Signal Decomposition Method for Correcting the Distorted Calibration Signals of Pressure Sensors
Yongsheng Li,Zhenjian Yao,Lixian Mao,Bo Shi,Lei Yao,Jinlin Song
DOI: https://doi.org/10.1109/tim.2024.3413141
IF: 5.6
2024-06-25
IEEE Transactions on Instrumentation and Measurement
Abstract:The dynamic calibration accuracy of pressure sensors with shock tube systems is often limited by the distorted calibration signal due to the interferences of nonuniform shock waves, vibrations, and complex noise. Signal decomposition has been verified to be a feasible way to correct the distorted calibration signals. However, the component loss problem in signal decompositions is a pain point that reduces the reliability of the calibration signal. In this article, a convolutional neural network (CNN)-assisted adaptive signal decomposition method is proposed to solve the component loss problem to further improve the calibration signal quality. First, the empirical mode decomposition (EMD) is used to adaptively extract the coarse ringing component from the distorted calibration signal. To effectively compensate the component loss problem of the coarse ringing component, a loss compensation model (LCM) is established by the CNN. Meantime, a dataset construction algorithm is proposed to improve the LCM accuracy based on the amplitude adjustment range and the autocorrelation function (ACF). The corrected calibration signal is finally obtained by the sum of the reconstructed ringing component and the preestimated trend from EMD results. A series of simulations and actual calibration experiments for two types of pressure sensors are carried out with a shock tube system to verify the performance of the proposed method. Results show that the proposed method is able to solve the component loss problem in signal decompositions and improve the quality of the calibration signals effectively. The mean absolute error (MAE) and root mean squared error (RMSE) of the amplitude-frequency characteristic (AFC) and phase-frequency characteristic (PFC) obtained by the proposed method are 0.13 and 0.31 V as well as 5.57° and 8.49°, respectively, which is about 1/8 and 1/5 as well as 1/6 and 1/6 times of the values obtained by the distorted signal. Furthermore, comparative experiments also demonstrate the superiority of the proposed method over the frequently-used methods in both calibration signal correction capability and robustness.
engineering, electrical & electronic,instruments & instrumentation