Comparative study of three rapid methods for Vibrio parahaemolyticus detection in aquatic products

PEI Lin,LU Jing-guang,LUAN Cheng-zhang
2013-01-01
Abstract:Objective To compare the specificity and sensitivity of three rapid methods for Vibrio parahaemolyticus detection in aquatic products.Methods The specificity and sensitivity were detected seperately by Fluorescence quantitative PCR,LAMP and color medium method on 13 positive and negative reference strains,and comparative analysis was performed to the results.Results PCR & LAMP methods show high specificity compared to color medium method in V.parahaemolyticus detection.LAMP can dectect 10 cfu / ml of V.parahaemolyticus,showing the highest sensitivity,and the sensitivity of PCR is 800 cfu / ml which takes the second place.The color medium method has the lowerst sensitivity which is 6500 cfu / ml.Conclusion Among three rapid detection methods for V.parahaemolyticus detection in aquatic products,PCR & LAMP methods show high specificity.LAMP shows the highest sensitivity,PCR takes the second place,and the color medium method is the lowerst.
What problem does this paper attempt to address?