Application of biodegradable screws in the treatment of hallux valgus deformity with distal chevron osteotomy

Xu Hai-lin,Fu Zhong-guo,Zhang Dian-ying,Wang Tian-bing
DOI: https://doi.org/10.3969/j.issn.1673-8225.2012.12.024
2012-01-01
Abstract:BACKGROUND:Distal chevron osteotomy is a common treatment for hallux valgus.But there is still controversial about the clinical outcome of biodegradable screws.OBJECTIVE:To evaluate the effect of biodegradable screws fixation for distal chevron osteotomy in the treatment of hallux valgus.METHODS:Eight patients(eight feet) with moderate hallux valgus deformity were treated by modified chevron osteotomy,and then,one 2.7 mm biodegradable screw was used for internal fixation.After operation,patients were asked to walk in a wooden-soled shoe for 6-8 weeks.RESULTS AND CONCLUSION:All patients were followed up for 28-46 months.There was no nonunion,delayed union or infection.The hallux valgus angle was improved 15°-21°,with a mean of(17.63±2.07)°.The intermetatarsal angle was improved 7°-9° with a mean of(8.00±0.76)°.The scores of Hallux Metatarsophalangeal-Interphalangeal Scale issued by the American Orthopaedic Foot Ankle Society were significantly increased from(70.13±7.10) points before operation to(92.75±7.30) points after operation(P < 0.05).It is indicated that biodegradable screw fixation for chevron osteotomy in the treatment of hallux valgus deformity is effective and reliable.
What problem does this paper attempt to address?