Approach to eliminate DC-link voltage pulsations of voltage-source PWM rectifier

CHEN Jian-sheng,ZHANG Wei
DOI: https://doi.org/10.3969/j.issn.1001-4551.2012.09.023
2012-01-01
Abstract:The stability of the DC-link voltage is a main target of the grid-connected PWM rectifier.When the grid voltage is unbalanced and(or)harmonically distorted,the conventional control strategy can't eliminate the pulsation of DC-link voltage.In order to solve this problem,Firstly,the effect of unbalanced and 5th and 7th harmonics to the VSR was analyzed;and then,an approach based on PI-R controller was proposed,with detail calculation of the current references and designation of current controller.Simulation results of a 1 MW VSR indicate that the proposed control strategy can significantly reduce the DC-link voltage pulsation,enhance the operation of the DC-link capacitor and the associated load safely.
What problem does this paper attempt to address?