Study on the Precise Phasor Calculation Based on Constant Sampling Frequency

LIU Bing-xu,ZHAO Jian-guo,GAO Hou-lei
DOI: https://doi.org/10.3969/j.issn.1672-3961.2005.06.011
2005-01-01
Abstract:Discrete fourier transform(DFT) is the basic method for measuring the phasor of power system in real-time.The sampling frequency of PMU is constant because of the synchronization of its phasor measuring.As system frequency changes,the error of measuring phasor is avoidless.In this paper the variation of measurement error is analyzed and the relation between error of angle and the selection of reference point in the data window summarized.A new method to revise the phasor by the measuring frequency is presented.Simulation result shows that the measuring error of magnitude and angle can reduce greatly using this method.
What problem does this paper attempt to address?