The Value of Ultrasonography in Diagnosis of Carpal Tunnel Syndrome

吴道珠,罗洪霞,黄品同,王慧丽,杨琰,洪建军,李志杰
DOI: https://doi.org/10.3969/j.issn.1006-9011.2008.11.025
2008-01-01
Journal of Medical Imaging
Abstract:Objective:To evaluate prospectively the accuracy of ultrasonography in diagnosis of carpal tunnel syndrome(CTS).Methods:Forty-four wrists in 37 CTS patients and 80 wrists in 40 asymptomatic volunteers were imaged using a real-time ultrasound scanner with a 7~14 MHz linear-array transducer.The cross-sectional area and flattening ratio at the level of the distal radius.The pisiform bone and the hook of hamate bone of the proximal carpal tunnel were measured.Data from the patient group and control group were compared to determine the statistical significance.The accuracy of the ultrasonographic diagnostic criteria for carpal tunnel syndrome was evaluated using receiver-operating characteristic(ROC) analysis.Results:All measurements showed significant differences between patients and controls.Increased cross-sectional area of the median nerve was the most predictive value of carpal tunnel syndrome.Using the ROC curve,a cut-off value of 9.5mm2 at the level of pisiform bone provided a diagnostic sensitivity of 88% and specificity of 87.5%.Conclusion:Sonographic measurement of the median nerve cross-sectional area is useful and dependent for the diagnosis of carpal tunnel syndrome.
What problem does this paper attempt to address?