Effects of feed C/N ratio on biological nitrogen and phosphorus removal in spiral up-flow reactor system

Luo Guyuan,Yang Yang,Xu Xiaoyi,Li Na
2009-01-01
Abstract:To investigate the effects of feed water C/N ratio on biological nitrogen and phosphorus removal in spiral up-flow reactor system,different feed water C/N ratios were designed,that was from 7 to 13,to study the variations of COD、total phosphorus and nitrogen.The results show that the C/N ratio has no obvious effect on the removal of COD and total phosphorus and the average removal rate is 95.2% and 93.9%,respectively.When the C/N ratio is lower than 9.4,the removal rate of total nitrogen increases as the C/N ratio rapidly.However,while the C/N ratio is higher than 9.4,the removal rate of total nitrogen stabilizes at 81.1%~85.6%.The nitrification of the system is more stable and the ammonia nitrogen removal rate remains at 90.5%~98.8%.Meanwhile,the denitrification of the system strengthenes with the increase of the C/N ratio and the effluent concentration of nitrate nitrogen decreases gradually.