Association of blood lead levels with preeclampsia: A cohort study in China
Su Zhen Wu,Huan Ying Xu,Ying Chen,Yu Chen,Qiao Ling Zhu,Min Hua Tan,Miao Miao Zhang
DOI: https://doi.org/10.1016/j.envres.2021.110822
IF: 8.3
2021-04-01
Environmental Research
Abstract:<h3 class="u-h4 u-margin-m-top u-margin-xs-bottom">Background</h3><p>Preeclampsia is the main cause of maternal and perinatal death, especially in developing countries. Multiple studies suggest that blood lead levels in pregnancy are a risk factor for preeclampsia, even with low levels of blood lead. But less knows the dose-effect relationship of preeclampsia in low blood lead levels.</p><h3 class="u-h4 u-margin-m-top u-margin-xs-bottom">Objectives</h3><p>This study aims to assess the association between blood lead levels and preeclampsia and to explore its dose-effect relationship between low blood lead levels and preeclampsia.</p><h3 class="u-h4 u-margin-m-top u-margin-xs-bottom">Methods</h3><p>The retrospective cohort study was consecutively conducted in a comprehensive tertiary hospital in Foshan city of Guangdong Province, China, from August 1, 2019, to November 30, 2019. Blood lead levels were measured in maternal whole blood in 12–27 (+6) weeks of pregnancy, using atomic absorption spectrometer. Preeclampsia diagnosis was ascertained from the electronic medical records system. The risk of preeclampsia was estimated by multivariable logical regression analysis, and a two-stage linear regression model was established to find out the dose-effect.</p><h3 class="u-h4 u-margin-m-top u-margin-xs-bottom">Results</h3><p>A total of 2174 people were included in this study, and 59 (2.7%) women developed preeclampsia. The dose-effect analysis revealed a non-linear association between blood lead levels and the risk of preeclampsia, with a cut-off point at 4.2 μg/dl. When blood lead levels were over 4.2 μg/dl, the risk of preeclampsia increased significantly with an increase in blood lead levels (OR = 2.05, 95%CI: 1.50, 2.81). In the multivariate regression models, per 1 μg/dl increment in blood lead levels was associated with 43% higher risk of developing preeclampsia (OR = 1.43,95%CI:1.17,1.74). Moreover, the association between blood lead levels and preeclampsia was stable in different subgroups.</p><h3 class="u-h4 u-margin-m-top u-margin-xs-bottom">Conclusions</h3><p>Low levels of lead exposure had a dose-effect relationship of preeclampsia, with a cut-off point at 4.2 μg/dl. Blood lead levels had a non-linear association with preeclampsia. When the blood lead levels were higher than 4.2 μg/dl, the risk of preeclampsia increases by 105% for every 1 μg/dl increase in blood lead levels.</p>
environmental sciences,public, environmental & occupational health