Study about induced current law by EMP on transmission line

LI Bao-zhong,HE Jin-liang,ZHOU Hui,CHENG Yin-hui,MA Liang,WU Wei,LI Jin-xi
DOI: https://doi.org/10.3969/j.issn.1672-2892.2010.01.009
2010-01-01
Abstract:The induced current law on transmission line was studied in electromagnetic pulsed environment.The variety laws including induced current,load voltage and the power were researched according to the following situations:one terminal was in short-circuit state and the other terminal was linked with resistance;two terminals were connected with different resistances respectively.The way of non-contact pulsed current injection was taken on the experiment,and the theoretical analysis was done with the transmission line theory model.The results showed that both ways were complied with the identical rule,and in electromagnetic pulsed environment the induced current on transmission line and the voltage on the end port resistance had direct relationships with the values of load.The dissipative energy by the resistance would reach the maximum value when special resistance values were selected.