Optimization method of fuzzy logic controller and its application in compensation of sensors

Jin Dongming
2007-01-01
Abstract:An error collection method for a kind of pressure sensor based on zero-order T-S fuzzy logic controller is presented.Simulated annealing algorithm is used to optimize the parameters of the fuzzy rules.After the temperature compensation,the error is corrected within ±0.3 %,and the temperature coefficients are reduced greatly.Compared to other compensation techniques,it is a new,efficient compensation method that not only increases the compensation precision but also maintains the fast calculation ability of the zero-orde T-S fuzzy logic controller.
What problem does this paper attempt to address?