Development of Rapid Assay for H7N9 Influenza Virus by Loop-Mediated Isothermal Amplification Method

Dong Zhizhen,Zheng Wenjie,Wang Naifu,Zhao Xiangping,Wu Dongxue,Wang yuling,Ma Jing,Jia Runqing,Wang Jianhua,Zhang Xiaoguang
DOI: https://doi.org/10.3969/j.issn.1005-944X.2013.07.025
2013-01-01
Abstract:Objective To set up a loop-mediated isothermal amplification(LAMP)assay for quick detection of H7N9 avian influenza virus. Methods The HA gene and NA gene of avian influenza virus subtype H7N9 were downloaded from GISAID database and analyzed using MegAlign tools of software DNAStar.The outer primers and inner primers of LAMP were then designed according to their conserva- tive region using software PrimerExplorer V4. The fragment of subtype H7N9 sequence was also ampli- fied and cloned to serve as the positive standard and its LAMP reaction condition and reaction system were optimized in this experiment.Results The results showed that the LAMP assay had a detection limit of 10 DNA copies. The primers used in this assay showed the specificity for H7N9 avian influenza A virus and did not amplify H1、H3、H5 subtype AIV or Newcastle disease virus.Conclusion It is indicated that the LAMP assay is a simple, rapid, accurate, sensitive and specific method for detecting H7N9 AIV. This assay offers a new method and idea for detecting avian influenza virus.
What problem does this paper attempt to address?