Use ICRU83 Report to Evaluate the Advantages and Disadvantages of Two Localization Methods for Nasopharyngeal Carcinoma in Traditional 2D Radiotherapy

Lu-chao ZHU,Li-wan SHI,Qin LIN
DOI: https://doi.org/10.3969/j.issn.1005-202X.2012.03.007
2012-01-01
Abstract:Objective: We use ICRU 83 report to compare the effectiveness of two image acquiring methods: X-ray simulator and CT simulation system,and the dose distributions in the tumor target regions and adjacent organs at risk of each system in nasopharyngeal carcinoma(NPC.Methods: X-ray simulator and CT simulation system were applied to a cohort of 10 patients,DR and CT images were gained.The doses of target volume or related volume were determined by using a treatment planning system(TPS).Results: CT images delineated larger clinical target volume 1(CTV1 and clinical target volume 2(CTV2),and smaller target volume compared to DR images(P< 0.05).DR images assigned significant larger volume and higher dose to the following organs at risk compare to CT images: pituitary,optic chiasm,optic nerves,submandibular glands,lens,temporal lobe,maxillary sinus and oral cavity.No remarkable volume and dose differences between two imaging systems were observed in these following organs at risk: brain stem,spinal cord,parotids,temporomandibuler joint,mandibla and cochlea.Conclusions: Compared to DR images,CT simulation system increases target volume dose and decreases volume of target.Moreover,CT images reduce the dose and volume of surrounding organs at risk,which can prevent the occurrence of side effects in radiotherapy.
What problem does this paper attempt to address?