Flow Cytometry Protocols on Algal Cell Counting and Live/Dead Assay for Water Supply

Huiting CHEN,Yi TAO,Jia ZHU
DOI: https://doi.org/10.3969/j.issn.1672-0318.2013.01.005
2013-01-01
Abstract:With two typical strains in China waters as studied subjects,flow cytometry protocols for algal cell counting through Caltag counting beads and for algal live/dead assay through SYBR green I and propidium iodide were established by using Microcystis aeruginosa and Chlorella ellipsoidea.The protocols were adopted for cell counting and live/dead assay of the algal cells with UV-C disinfection treatment at 0-200 mJ.cm-2.The results indicate that the cell counting data based on flow cytometry analysis were well linear-correlated with that of microscopic analysis(R2 = 0.980) while saving the detection time to less than 5 min.Live/dead assay data based on flow cytometry were well linear-correlated with the mixture setting with R2 of 0.999 for M.aeruginosa and R2 of 0.995 for C.ellipsoidea,indicating the protocol for live/dead assay was precise.The flow cytometric results of cell counting and live/dead assay of the algal samples with UV-C disinfection treatment show that the protocols were accurate and precise.