Determination of DMF With High Performance Liquid Chromatography Applied in Middle-Controlled Analysis of Wastewater Treatment

Chen Le,Wang Yuping,Peng Panying,Liu Guoqing
DOI: https://doi.org/10.3969/j.issn.1672-1292.2011.04.018
2011-01-01
Abstract:A method for DMF in waste water and organic phase with high performance liquid chromatography(HPLC) was established.HPLC was performed on a Krornasil-C18 column,using methanol and water(15∶85) as mobile phase and the detection wavelength of 205nm.The results show that the calibration curve is linear in the range of 3.06mg/L-38.28mg/L for concentration of DMF(r=0.9997),precision is high,and its relative standard deviation is 1.03%.The recovery DMF is between 99.86%-101.09%.The method is rapid,accurate,reproducible and can be used for quantitative analysis of DMF in wastewater and provided as a good central control analysis method of recycling conditions of wastewater.
What problem does this paper attempt to address?