Dynamic centrifuge model test of a soil-structure interaction system

Liu Jingbo,Liu Xiangqing,Wang Zonggang,Zhao Dongdong
DOI: https://doi.org/10.15951/j.tmgcxb.2010.11.015
2010-01-01
Abstract:Two dynamic centrifuge model tests of an underground structure at different depths in sandy soil are performed to investigate the seismic response behavior of the dynamic soil-structure interaction system. The tests are performed at 50 gravitational accelerations and the input motion is Kobe wave. The design of the tests is presented and some of the test results, including acceleration, earth pressure, displacement, and strain responses, are provided. The maximum bending strain of vibration occurs at the column top, indicating that the column is the most unfavorable member of the structure during the earthquake and that the column top is more disadvantageous than the column bottom. The total earth pressure increases under seismic loads and maintains at a high level after the vibration. Both the maximum earth pressure increment and maximum total earth pressure occur at the corner of the bottom plate. The comparison between the test results at two burial depths indicates that the burial depth is an important factor influencing the seismic response of an underground structure. The seismic response of the structure at the prototype burial depth of 5 m is less favorable than that of 2.5 m. The peak values of the additional bending strain responses due to earthquake at some observation positions are close for the major and the auxiliary measuring cross sections, and the shapes of the strain time history curves are similar, which indicates good integrity of the structure model under seismic loads.
What problem does this paper attempt to address?