Methodology Evaluation of Liquid Immune Colloidal Gold Technique in the Determination of Plasma Cystatin C

程黎明,朱晓华,朱耀武,管青
DOI: https://doi.org/10.3969/j.issn.1673-8640.2010.03.017
IF: 1.865
2010-01-01
Laboratory Medicine
Abstract:Objective To evaluate the methodology performance of determining cystatin C(Cys C) by liquid immune colloidal gold reagent on the automatic biochemical analyzer and the correlation between Cys C results and glomerular filtration function.Methods Cys C concentration was determinated by liquid immune colloidal gold reagent and particle-enhanced nephelometric immunoassay(PENIA) respectively.The precision,linearity and interference of Cys C liquid immune colloidal gold reagent,its correlation and the bias with PENIA were evaluated.The correlation analysis was performed between plasma Cys C concentrations and glomerular filtration rate(GFR) determined by 99mtechnetium-labeled diethylenetriamine penta-acetic acid(99mTc-DTPA) renal dynamic imaging of 97 patients with chronic renal disease.The receiver operating characteristic(ROC) curve was used to evaluate the value of plasma Cys C in the diagnosis of renal function reduction.Results The total coefficients of variation(CV) of samples with low,medium and high concentrations of Cys C were 5.27%,5.23% and 2.81% respectively.This reagent showed good linearity ranged from 0.54 to 8.65 mg/L.Hemoglobin(10 g/L) and bilirubin(300 mg/L) in the samples had no significant interference(10%) in the assay.The interference was more than 10% for the samples of low Cys C concentration when triglycerides(TG) ≥20 mmol/L,while the interference was not significant to the samples of high Cys C concentration.The results by liquid immune colloidal gold reagent correlated well with those by PENIA(r=0.99,P0.01).There was no significant bias between these two methods(P0.10).However,the values were slightly higher than those from PENIA with the mean bias of 0.27 mg/L.Plasma Cys C concentrations showed significant correlation with GFR(r=-0.829,P0.001).The area under the ROC curve(AUC) was 0.826 [95% confidence interval(CI): 0.716-0.936] for plasma Cys C in the diagnosis of renal function reduction.When the optimal cut-off value(1.11 mg/L) was used to discriminate the elevated values from the normal values,24.3% of the patients with GFR≥80 mL/(min·1.73 m2) showed increased concentration of Cys C.Plasma Cys C concentrations increased in 70% of the patients with GFR between 50 and 80 mL/(min·1.73 m2) and all the patients with GFR≤50 mL/(min·1.73 m2).Conclusions The precision,linearity and interference of Cys C liquid immune colloidal gold technique on the automatic biochemical analyzer are suitable for the requirements of clinical application.The liquid immune colloidal gold technique correlates well with PENIA,but there exists bias between these two methods.Plasma Cys C is an ideal indicator in the evaluation of glomerular filtration function.
What problem does this paper attempt to address?