Study on Accurate Radar Cross Section Measurement in Farfield

LI Nan-jing,ZHANG Lin-xi,XU Jia-dong,YE Xiu-nan,LI Ping
DOI: https://doi.org/10.3969/j.issn.1004-7859.2006.08.020
2006-01-01
Abstract:Traditional method of indoor RCS measurement is the single frequency(CW) method.For low backscattering target measurement,a cancelling system is introduced in the testing system to get more accurate result, which reduced more than 20 dB of chamber background level.But there exists some error in the above scheme: the shadowing of target can′t be compensated,and the compensation system becomes easily unstable.Another scheme is introduced in this paper,that is analyzing testing data in time-domain with FFT by frequency sweeping measurement,and by proper setting,very accarated result can be obtained.The new method has only a simple frame and can get more information,without complex manual adjusting system,such as chamber background cancelling system.
What problem does this paper attempt to address?