Preparation and Quality Control of 1% Lincomycin Hydrochloride Cream

Shu Bing,Fang Yan,Xiao Ming,Zhang Shantang
DOI: https://doi.org/10.3969/j.issn.1008-049X.2008.09.016
2008-01-01
Abstract:Objective:To prepare lincoroycin hydrochloride cream and to establish a method for its quality control.Method:The cream was prepared with O/W as base.The content of the cream was determined by HPLC.Chromatographic determination was per- formed on Hypersil C_(18) column(250 mm×4.6 mm,5μm) with phosphoric acid buffer(adjusted to pH 6.8)-methanol (40:60) as the mobile phase and flow rate was 0.8 ml·min~(-1).Detection wavelength was at 214 nm,and the column temperature was 30℃.Result: The prepared cream was up to the standard stated in China Pharmacopeia.The linear range of lincomycin hydrochloride was 0.240 2 - 0.560 6 mg·ml~(-1)(r=0.999 8),and the average recovery was 99.7%.Conclusion:The preparation process of lincoroycin hydrochlo- ride cream was simple.The method of quality control was rapid and accurate.