Infrared Focal Plane Array Spatial Integral Sampling Noise Analysis and Test

GUO Shiyong,CHEN Qian,HAN Bangjie
DOI: https://doi.org/10.3969/j.issn.1671-637X.2011.01.014
2011-01-01
Electronics Optics & Control
Abstract:In the imaging process of staring Infrared Focal Plane Array(IFPA),the spatial-sampling frequency is determined by the physical size and spatial distance of detecting units.However,the spatial frequency of the detected scene is always higher than half of the sampling frequency of staring IFPA,thus under-sampling will happen,and the quality and utility of the image will be seriously degraded by aliasing noise.Staring IFPA spatial integral sampling theory was analyzed,then effects the physical size,spatial distance,geometric figure,arrangement manner of detecting units on spatial-integral sampling noise were discussed based on the focal plane array configuration.Two methods for aliasing noise testing,central Brillouin zone real/ fake spectrum integral ratio and micro shift correlation,were put forward and educed.
What problem does this paper attempt to address?