The Contrast Study of the Unenhanced and Enhanced Color Doppler Sonography in the Diagnosis of Vascular Diseases

LI Chaolun,WANG Wenping,HUANG Beijian,HE Nianan
DOI: https://doi.org/10.3969/j.issn.1008-6358.2007.05.050
2007-01-01
Abstract:Objective:To investigate the value of enhanced color Doppler sonography in the diagnosis of peripheral vascular diseases.Methods:Twenty-two patients were imaged with unenhanced and enhanced color Doppler ultrasonography(US)with Acuson 128-XP10 duplex system and ultrasound contrast agent SonoVue.The results were compared with those of angiography,surgery investigation,CT and MRI.Diagnostic confidence and agreement were obtained before and after the administration of contrast agents.Contrast enhancement duration was noted.Results:The confidence of diagnosis increased from 72.7%(16/22)to 100%(22/22).The sensitivity,specificity,positive predictive value and negative predictive value of unenhanced color Doppler US were 92.3%,22.2%,63.2% and 66.7%,respectively.Those of enhanced color Doppler US were 93.3%,100%,100% and 87.5%,respectively.The overall contrast enhancement duration was about 10min after the intravenous administration of ultrasacnd contrast agent with the infusion rate about 1ml·min-1.Conclusion:Enhanced color duplex scanning may improve the confidence and ability of diagnosis,especially in patients in whom conventional duplex scanning is difficult.
What problem does this paper attempt to address?