Treatment of bicondylar tibial plateau fractures by double plating or single lateral locked screw plating

CHEN Yi-xin,WANG Jun,XIONG Jin,LUO Dong-shan,QIU Yong
DOI: https://doi.org/10.3969/j.issn.1008-0287.2007.05.017
2007-01-01
Journal of Clinical Orthopaedics
Abstract:Objective To investigate the efficiency and complication of treating bicondylar tibial plateau fractures by medial and lateral double plating or single lateral locked screw plating.Methods In 31 cases of bicondylar tibial plateau fractures,20 cases had been fixed with double plate and 11 cases fixed with locked plate.Results The knee movement range,was 103.4°±21.9° and 108.2°±24.7°respectively,with no significant difference found between the two.In terms of the knee HSS scores,the scores was 74.9 and 75.6 respectively,with no significant difference;while 71% and 82% of the patients fixed with double plate or locked plate achieved satisfaction.The double plating patients had 6 cases of loss of bicondylar tibial plateau height and 3 cases of incision infection;by contrast,those for locked plating patients were 2 cases and 1 case.Conclusions Both methods can be used to treat bicondylar tibial plateau fractures effectively.
What problem does this paper attempt to address?