STUDY ON DISINFECTION OF HOSPITAL WASTEWATER USING DIAMOND ELECTRODE

Wang Zhen,Kong Defang,Wang Jiadao
2012-01-01
Environmental engineering
Abstract:Disinfection effect of hospital wastewater treatment was studied by a self-made electrolyzer device with the boron-doped diamond(BDD) electrode.In total reflux mode of hospital wastewater disinfection treatment,fecal coliform count was determinated using the multiple tube fermentation method.Those the boron-doped diamond(BDD) was used as electrode,the electrode spacing was 2mm,Cl-concentration of hospital sewage was 200 mg/L,pH value was in the range of 7~8,the current density was 8 mA/cm2 were optimal for the fecal coliform removal ratio of hospital sewage when the contact time was more than 9S,and the fecal coliform counts in the effluent shall not exceed 500 MPN/L,which was accorded with medical institution sewage discharge standard value.The self-made electrolyzer device with the boron-doped diamond(BDD) electrode for hospital wastewater treatment needed not add chemicals,which was good disinfection effect for fecal coliform.
What problem does this paper attempt to address?