A Study on Temperature Compensation Structure

谢勇,王兵,任静斌
DOI: https://doi.org/10.3969/j.issn.1006-9348.2008.08.080
2008-01-01
Abstract:This paper presents a simple and effective method for compensating thermal deformation of the optical system resulting from off-axis error.After modeling a crude tracking optical system and making temperature analysis of the optical system by using finite element analysis software,a linear temperature field caused by the CCD high temperature is obtained,and the maximum temperature and the minimum temperature of all components are also obtained.Then the temperature field is loaded to the structure analysis.The thermal deformation of all parts of the optical system is obtained.The analysis results show: Despite in the direction of the Z-axis the largest displacement of thermal deformation in the Shell of the optical system reaches 0.116 mm,and the greatest negative displacement reaches-0.104 mm in the temperature field,the Zaxis direction displacements of the units near the Lens are no more than 0.020 mm.the thermal expansion of supporting pieces of the optical components effectively compensate the shell thermal drift.These data show that the thermal compensation method is an effective method and can be used for the actual work.
What problem does this paper attempt to address?