A flow-injection ultrafiltration sampling chemiluminescence system for on-line determination of drug–protein interaction

Zhouping Wang,Zhujun Zhang,Zhifeng Fu,Yan Xiong,Xiao Zhang
DOI: https://doi.org/10.1007/s00216-003-2125-5
2003-01-01
Analytical and Bioanalytical Chemistry
Abstract:A flow-injection ultrafiltration sampling chemiluminescence system for on-line determination of cimetidine–bovine serum albumin (BSA) interaction is proposed in this paper. Cimetidine can be oxidized by N -bromosuccinimide (NBS) and sensitized by fluorescein to produce high chemiluminescence emission in basic media. The concentration of cimetidine is linear with the CL intensity in the range 3×10 −7 –1×10 −4 mol L −1 with a detection limit of 1×10 −7 mol L −1 (3 σ ). The drug and protein were mixed in different molar ratios in 0.067 mol L −1 phosphate buffer, pH 7.4, and incubated at 37 °C in a water bath. The ultrafiltration probe was utilized to sample the mixed solution at a flow rate of 5 µL min −1 . The data obtained by the proposed ultrafiltration flow-injection chemiluminescence method was analyzed with Scrathard analysis and a Klotz plot. The estimated association constant ( K ) and the number of the binding site ( n ) on one molecule of BSA by Scrathard analysis and Klotz plot were 3.15×10 4 L mol −1 and 0.95, 3.25×10 4 L mol −1 and 0.92, respectively. The proposed system proved that flow-injection chemiluminescence analysis coupled with on-line ultrafiltration sampling is a simple and reliable technique for the study of drug–protein interaction.