Finite Element Analysis on Submaxilla Anterior Guidance Subjected to Forsus and Optimal Angle of Orthopedic Force

YAN Gong-xing,LIU Zhan-fang
DOI: https://doi.org/10.3321/j.issn:1000-5404.2009.19.021
2009-01-01
Abstract:Objective To explore the stress and displacement distribution of submaxilla subjected to Forsus,and investigate the optimal angle of orthopedic force in order to provide biomechanical basis for new appliances designation.Methods A health 12-year-old clinical volunteer with Angle classⅡ malocclusion was subjected.Helical CT and 3-D image technique were used to finish the primary model reconstruction.And a 3-D finite element(FE) model of the submaxilla,dentition and archwires and brackets was constructed with ABAQUS software.Then Forsus orthopedic force application based on the FE model were simulated under 5 different designed conditions.Results Under all 5 loading conditions,the Von Mises equivalent stresses level on the dentition and archwires and brackets are higher than on the submaxilla,the highest stress was on the archwires and brackets.Stress centralization on the submaxilla mostly located at the condylar and alveolar ridge,the highest stress of the submaxilla was on the condylar,and the largest displacement of submaxilla was on the chin basically.Plastical strain were appeared on the condylar.Conclusion The optimal angle of orthopedic forsus force is between 0° and 25°.