Anatomic and "L"-shaped Locking Compression Plate for Treatment of Complex Pilon Fracture

Zhan Yulin,Xia Ronggang,Chen Yang
2011-01-01
Abstract:Objective To explore the clinical effectiveness and skills of using the anatomic and "L"-shaped locking compression plate(LCP) to treat the complex Pilon fracture.Methods A total of 17 patients with Pilon fractures were treated with open reduction and fixation with the minimally invasive techniques,and internal fixation with the "L"-shaped locking compression plate(LCP) and bone graft.Results Fifteen cases' incision healed by first intention,the edge of incision necrosis occured in 2 cases,but healed after dressing change.The average follow-up period was 15.5 months(8~18 months).The average time of healing fracture was 16.3 weeks(14~20 weeks).According to American Orthopedics Food Ankle Society scale,the results were evaluated as excellent in 12 cases,good in 4 cases,fair in 1 case.The rate of excellent and good was 94.1%.Conclusion The treatment of Pilon fracture with anatomic "L"-shaped locking compression plate is effective.During the operation,the key step is to restore the shape of the ankle joint and the length of the lower normal gravity line.