A Comparative Study of Imaging Methods in Observing Cemet Leakage after Percutaneous Vertebroplasty

陈颐,颜志平,王建华,王小林,罗剑钧,刘清欣
DOI: https://doi.org/10.3969/j.issn.1008-6358.2009.04.044
2009-01-01
Abstract:Objective:To evaluate the clinical value of spiral CT,X-ray,and DynaCT in observing cement leakage after percutaneous vertebroplasty (PVP). Methods:PVP was perfomed in 18 patients with 22 vertebral metastases. Spiral CT,X-ray,and DynaCT were used to observe cement leakage after PVP. The sensitivity and specificity of X-ray and DynaCT were calculated according to the standard of spiral CT. Results:The technique success of PVP in 22 vertebrae was 100%. The amount of cement injected varied from 2.0 to 6.0mL,with mean of 3.5mL. There was no neural injury or pulmonary embolization occurred. Spiral CT demonstrated 15 cement leakage in 22 vertebrae,with leakage rate of 68.2%. X-ray demonstrated cement leakage in 7 vertebrae,with leakage rate of 40.9%,sensitivity of 55.6%,and specificity of 100.0%. The cement leakage rate and leakage pattern showed by DynaCT was the same as spiral CT. Conclusion:Spiral CT is the optimal choice of demonstrating cement leakage after PVP. DynaCT can substitute for spiral CT in demonstrating cement leakage.