Assessment the Accuracy in Measuring the Distance Between Rectal Cancer and Anus with Experimental CT Vrtual Coloscope 360° Virtual Dissection

吴兴旺,刘斌,赵红,余永强
DOI: https://doi.org/10.3969/j.issn.1001-9324.2008.02.030
2008-01-01
Abstract:Objective To assess the accuracy of 360° experimental CT virtual dissection in measuring the distance between rectal cancer and anus. Materials and Methods 10 artificial rectal tumor-like lesions were placed with glue in a thoroughly cleaned porcine colon(overall length, 20 cm) that was distented with air and submerged in a water phantom and scanned on a 64 MDCT(GE Light speed). The data were reconstructioned every 0.625 mm and reviewed on GE AW 4.2 workstation to measure the lesions' distance to the starting point on the 360° virtual dissection. Taking out the average value after measuring 10 times and compared with the actual distance. Results On 360° virtual dissection, 10 lesions' distance were measured exactly and the most results were close to the actual distance, only a few exceed the actual distance slightly.The actual distance was 145-10 mm, mean value was 77.5 mm, the resalt measured on 360° virtual dissection and the mean value were 142.4-9.6 mm and 76.5mm, respectively. There were no significant difference between them(t=0.049, P=0.961). Conclusion The 360°virtual dissection of 64 MDCT could measure the distance between the rectal cancer and anus, and provide important information for surgery.