Experimental Study of Membrane Action of Composite Floor Slabs under Fire

Li Guoqiang,Zhang Nasi
DOI: https://doi.org/10.15951/j.tmgcxb.2010.03.006
2010-01-01
Abstract:In order to vertify the existence of membrane action in steel-concrete composite floor slabs with steel decks under fire, as well as to look into the failure mechanism, the temperature field and strain variation of reinforcement and concrete in the slabs under elevated temperatures, four full-scale slab tests under the ISO834 standard fire were preformed. The temperatures of the furnace, the slabs and the reinforcement, the strain of the reinforcement and concrete in the slabs, and the deflection of the slabs were measured. According to the test results, the test phenomena were explained and analyzed, to verify the existence and effect of membrane action in composite floor slabs under fire. Based on the analysis, it is concluded that it may be unnecessary to provide additional fire protection for the slabs and the secondary beams due to the membrane action.