Implementing Method of Precise Time Synchronization for Measurement and Control

谢昊飞,王平,张健,王浩
DOI: https://doi.org/10.3969/j.issn.1000-3428.2008.10.089
2008-01-01
Abstract:The different implements of the IEEE1588 are very important to the precise time synchronization.This paper expounds the structure of the PTP engine module,realizes the state machine of the PTP,the best master clock algorithm and the local time synchronization algorithm,and optimizes the process of receiving and sending the message.The experiment shows that the synchronization accuracy is in the range of 10 microsecond by using the implementing method in the paper and satisfies the need of the measurement and control field.
What problem does this paper attempt to address?