Rapid Determination of Free Amino Acids in Tea by NIR Spectroscopy.

DONG Er-hui,TAN Hong,YANG Hong-bo,ZHAO Hong-bo,MA Kai,YUAN Xin
DOI: https://doi.org/10.3969/j.issn.1004-3268.2012.10.011
2012-01-01
Abstract:In order to establish a method for rapidly detecting free amino acids of tea,162 green tea samples of different origins in Guizhou province were detected by near infrared spectroscopy(NIR).Combining with PLS,a mathematical model of amino acids in green tea was set up.According to the standard normal variate processing method,the selected spectra ranged between 6 657.74-6 178.16,5 793.11-5 688.98,4 493.33-4 350.62 cm-1.The number of principal factor was 11.The correlation coefficient of the model and the root mean square error of crossvalidation(RMSECV) were 0.981 56 and 0.501,respectively.Moreover the correlation coefficient and the root mean square error of prediction(RMSECV) between predicted value of the model and chemical determination value were 0.998 and 0.312,respectively,and the RSD was below 0.4% in the stability test.The result showed that the combination of FTIR spectroscopy and chemometrics was proved to be quick and reliable for free amino acid detection,which would satisfy the requirements of detection.
What problem does this paper attempt to address?