Degradation of Aniline Using E-Fe-PDS Process in Internal Circulation Batch Reactor
Chunwei YANG,Wenwen GUI,Shuhao ZHANG,Xin TIAN,Yaheng DAI,Xiaoyue DUAN
DOI: https://doi.org/10.3969/j.issn.1003-6504.2017.04.029
IF: 11.4
2017-01-01
Environmental Science & Technology
Abstract:A comparative experimental study on aniline degradation in water was conducted involving three different technical processes i.e.electrolysis,electro-Fenton and E-Fe-PDS (electro-assisted Fe2+ activated peroxydisulfate).The experiment was conducted with a bench-scale internal circulation batch reactor (ICBR),within which was fixed a graphite rod as anode and iron chips as cathode,as well as an aerator at the bottom.The operation parameters affecting aniline degradation were investigated,which included electric voltage,pH value,Na2S2O8 concentration and FeSO4 concentration.This experimental study suggested that of the three processed E-Fe-PDS was the best in aniline degradation with aniline removal rate of 95.7%,and its reaction process fitted with the pseudo-first order kinetics model.In addition,in the case of the reaction using E-Fe-PDS,the polymerization intermediates produced during the reaction process,detected by HPLC,were of fewer types but higher mineralization rate,in comparison with the electrolysis and electro-Fenton processes;however,some intermediate products such as 4,4'-diamino biphenyl,so called the secondary pollutants,were likely found as well,which were difficult to decompose.So,careful assessment is needed before the E-Fe-PDS technology is put into use in practice.