Research of Heat Exchanger Structure and Performance with Continuous Helical Shaped Baffles

Yi-Xin SONG,Yu-Fei TAN
DOI: https://doi.org/10.3969/j.issn.1002-6339.2009.03.009
2009-01-01
Abstract:Heat exchanger with continuous helical shaped baffles is not widely used because of manufacturing process difficuty.The article introduces a new approach of central tube configuration and proposes a new design method based on the spiral angle and helical enveloping surface of continuous helical baffle plate.The pressure drop in shell,the heat transfer coefficient for continuous helical baffle heat exchanger and widely used quarter-ellipse helical baffle heat exchanger are calculated with Fluent software.The simulation results show that the heat transfer capability of heat exchanger with the continuous helical baffle has been doubled,and the combined performance is 30 percent higher than that of heat exchanger with quarter-ellipse helical baffle. The leakage among baffles decreases the pressure drop of quarter-ellipse helical baffle heat exchanger,but reduces the heat transfer capability at the same time.This research is helpful to technological progress and application of the continuous helical baffle heat exchanger.
What problem does this paper attempt to address?