IMU Integrated Calibrating Technique with Skewed Sensor Axes

GUO Peng-fei,REN Zhang
DOI: https://doi.org/10.3969/j.issn.1005-6734.2007.03.028
2007-01-01
Abstract:The low-cost inertial measurement unit (IMU) includes three skewed fiber-optics gyroscopes (FOG) and three skewed MEMS accelerometers. Considering three FOGs and three accelerometers respectively as a whole,an integrated calibrating technique was advanced in which an equivalent transfer matrix replaced the traditional bias,the scale factor and the misalignment errors. Based on the experimental formulas for the low-cost skewed IMU’s temperature dependency and non-linearity,a new integrated calibrating model was developed which could compensate its temperature dependency and non-linearity. After testing in different temperature with rate table and marble plat,two applied models of angular velocity and acceleration were got via multiple linear regressions. The real-time compensation shows that the skewed IMU’s angular velocity error is less than 0.02 (°)/s with operating range of ±60 (°)/s,and its acceleration error is less than 0.003g for the temperature range(0℃to 24℃).