Abstract:The specific heat of typical bituminite,anthracite and lean coal was measured below the temperature 1200℃ with the differential scaning calorimeter(DSC).The influence on specific heat with same coal in different mass,heating rate and flow is studied.The results show that the specific heat of coal increases with the temperature;the specific heat of anthracite is the lowest at low temperature,the specific heat of bituminite is the highest at high temperature.The experimental condition has been optimized and confirmed for measuring specific heat of coal as follows: mass is 20mg,heating rate is 10℃/min and flow is 20mL/min.