Simultaneous Determination of Eight Sulfonamide Residues in Fish Muscle Using Matrix Solid-phase Dispersion Coupled with High Performance Liquid Chromatography Based on Low Toxic Solvent

ZHAO Hai-xiang,DENG Wei,SHANG Yan-fen,ZHAO Meng-bin,DING Ming-yu
DOI: https://doi.org/10.3321/j.issn:1002-6630.2009.04.036
2009-01-01
Abstract:A multi-residue analytical method for eight sulfonamides in fish muscle based on matrix solid-phase dispersion(MSPD) coupled with high performance liquid chromatography(HPLC) was developed.This method was environmentally friendly using ethyl acetate as the elution solvent.0.5 g of fish muscle mixed with 2 g of C18 packing material was grounded and filled into a SPE column.After washing with hexane,sulfonamides were eluted with ethyl acetate and determined using RP-HPLC with UV detector at 270 nm.Sulfonamides were separated on C18 column using 50 mmol/L NaH2PO4-acetonitrile(70:30,V/V) as mobile phase at a flow rate of 0.7 ml/min,and the column temperature was 30 ℃.The linear range of this method is from 0.010 μg/ml to 1.000 μg/ml with the correlation coefficient of over 0.9999.The spike recoveries are in the range of 76.0% to 115.0% and the relative standard deviation(RSD) is less than 6.4%(n = 6).The limit of detection is 0.020 μg/g in a 0.5 g of sample.