HPLC-MS method to investigate the bioequivalence of diltiatem extended action tablets

Leng Ye,Duan Hongfei,Yun Changhong,l D
2011-01-01
Abstract:Objective To establish an HPLC-MS method the determination of diltiatem and to investigate the bioequivalence in Chinese healthy volunteers.In a randomized,crossover study.Methods 20 healthy male volunteers were orally administrated with diltiatem extended action tablets(test sample and reference sample) 180 mg.The plasma concentration of diltiatem was determined by HPLC-MS method.The pharmacokinetic parameters were calculated and the bioequivalence was evaluated.Results The LLOQ of the HPLC-MS method for diltiatem in plasma was 0.4 ng/ml and the calibration curve was linear over the range of 0.4~400 ng/ml.The intra-and inter-run standard deviation was less than 15%.The main pharmacokinetic parameters of the test and reference drugs were as follows : tmax(22.3±7.3) h and(23.0±6.5) h,Cmax(54.32±25.73) ng·ml-1 and(55.63±27.19) ng·ml-1,t1 /2(8.8±2.5)h and(9.9±4.4) h,AUC0-60(1 465.3±686.3) ng·h·ml-1 and(1 539.6±692.9) ng·h·ml-1.The confidence interval(%) of Cmax、AUC0-60、AUC 0-are 88.5%~108.1%、88.7%~102.1% and 86.0%~100.2% through logarithmic transformation,Tmax was not statistically significant through non-parametric test.Conclusion Two formulations were bioequivalent.
What problem does this paper attempt to address?