Clinical Application of Detection of the Fusion Gene in Acute Promyelocytic Leukemia with Reverse-Transcriptase Real-Time Quantitative PCR

ZHAO Jun-feng,ZHU Ping,ZHANG Ying,DU Jin-wei,LIU Hong-xing,LIU Jing,ZHUANG Xin,QIU Zhi-xiang
DOI: https://doi.org/10.3760/j:issn:1009-9158.2006.05.012
2006-01-01
Abstract:Objective To compare different reverse-transcriptase real-time quantitative PCR (RQ-PCR) methods with two fluorescent dyes in the detection of the PML-RARα fusion gene in acute promyelocytic leukemia (APL). Methods The RQ-PCR method based on SYBR GreenⅠ and Eva Green respectively was established to detect the PML-RARα fusion gene expression.The expression of PML-RARα in 56 patients with APL was determined and the sensitivity of RQ-PCR was compared with that of the conventional nested RT-PCR. Ten patients newly diagnosed APL were randomizedly divided into two groups, one group receiving all-trans retinoic acid (ATRA) plus chemical therapy and another receiving ATRA plus As_2O_3.The transcript level of PML-RARα in patients was determined every three weeks after treatment.Results The RQ-PCR with both SYBR GreenⅠ and Eva Green could detect as low as 50 copies of PML-RARα. The sensitivity of RQ-PCR was a little bit lower than that of the conventional nested RT-PCR.However, RQ-PCR had accurate quantification of fusion gene transcripts and was less liable to the contamination. The PML-RARα plasmids of high (10~7 copies) and low (10~3 copies) level and a cDNA sample of a patient were tested 8 times in one PML-RARα PCR assay to calculate the intra-assay variability (CV). The CVs were 7.31%, 8.26% and 5.02%, respectively. The median of the PML-RARα fusion gene expression level in the patients with APL before treatment was 0.070 (range:0.018-0.799). The fluorescent intensity of Eva Green was four times higher than that of SYBR GreenⅠ.The transcript of PML-RARα fusion gene decreased rapidly in both treatment groups in two to four weeks after treatment. No expression of the fusion gene could be detected in 80% patients of both groups after two months. There was no significant difference between the two groups.Conclusion RQ-PCR can quantify the expression of fusion gene in minimal residual disease (MRD) accurately. Both Eva Green and SYBR GreenⅠ can be used in RQ-PCR with Eva Green being more sensitive and effective. The fusion gene expression level can be used for monitoring the therapeutic effect with different treatment strategies effectively.
What problem does this paper attempt to address?