Heat-Transfer Performance-Test Of A Prototype Plate-Fin Condenser-Boiler For Industrial Usage

Yy Wu,Yz Liu,Lf Chen,Yz Li,Hq Xie
DOI: https://doi.org/10.1016/0011-2275(92)90160-c
IF: 2.134
1992-01-01
Cryogenics
Abstract:A 1 metre long prototype plate-fin condenser-boiler section was constructed with two boiling channels on either side of a central condensing channel.Liquid nitrogen is evaporated inside the boiling channel at atmospheric pressure while the condensing nitrogen at a higher pressure returns to a reboiler and evaporates again in the reboiler due to electric heating. At heat fluxes less than 6000 w/m2 the total temperature difference for boiling and condensing heat transfer is less 1.1 K,decreased by 0.3--0.8 K in comparison with the practical operating condenser-boiler.
What problem does this paper attempt to address?