Evanuation of Double Balloon Endoscopy in the Diagnosis of Gastrointestinal Diseases

SONG Zhi-qiang,HUANG Yong-hui,DING Shi-gang,GU Fang,YAO Wei,ZHOU Li-ya,LIN San-ren
DOI: https://doi.org/10.3870/j.issn.1005-541X.2009.06.005
2009-01-01
Abstract:Objective To investigate the diagnostic value of double balloon endoscopy(DBE)in the patients with gastrointestinal diseases(especially with small intestinal diseases).Methods The clinical data and images form DBE of 50 consecutive patients form 2004 to 2009 in Peking University Third Hospital were analyzed.These patients were followed up by telephone.Results A total of 50 patients underwent 65 DBE procedures.Among all the patients,the onset with obscure gastrointestinal bleeding(OGIB)and abdominal pain or discomfort,the rate of definitive diagnosis was 84.0%,84.0% and 88.2%,respectively.The accuracy of BDE procedure was 90.5%,90.5% and 86.7%.The sensitivity of DBE for small intestinal diseases was 94.1%,94.4% and 90.0%.The specificity was 75.0%,66.7% and 80.0%.The positive predictive value was 94.1%,94.4% and 90.0%.The negative predictive value was 75.0%,66.7% and 80.0%.No difference was found in rate of definitive diagnosis(92.3% ∶75.0%)and the accuracy of DBE procedure(91.7% ∶88.9%)between the patients with different examining opportunities(P>0.05).Except one acute pancreatitis and aspiration pneumonia,no serious complications related with the DBE procedure occurred.Conclusion DBE with high diagnostic value and safety was a good method in the diagnosis of small intestinal diseases.There were differences in the diagnostic value among patients with different indications.The DBE examining opportunity had no influence on the diagnostic yield of OGIB.
What problem does this paper attempt to address?