Application of Autologous Transfusion in Liver Transplantation for Hepatocirrhosis

陈波,葛春红,林艳,刘银,周晔,唐晓峰
DOI: https://doi.org/10.13201/j.issn.1004-2806-b.2013.01.008
2013-01-01
Abstract:Objective:To investigate the application and safety of autologous blood transfusion on hepatocirrhosis patients who received liver transplantation. Method:Autologous blood was collected during liver transplantation surgery from 35 patients suffering from hepatocirrhosis with FCR-3000 automatic blood collecting system.Anticoagulantion,filter,centrifugation and washing was performed to generate red blood cells suspension which would be transfused autologously subsequently.We collected the quantity of blood allotransfused and autotransfused.Pre-and postoperation blood electrolytes and coagulation were examined and transfusion related adverse effect was monitored. Result:Three from 35 patients(8.6%) did not receive allotransfusion.The average quantity of red blood cell suspension transfused was(9800±5400) ml,from which the average autotransfused blood quantity was(5850±5000) ml(56.16%).The postoperational APTT,PT,TT and FB were significantly extended(P0.05).Moreover,adverse effects including fever,fat embolism and general infection were not observed. Conclusion:The application of autologous blood transfusion in liver transplantation performed on cirrhosis patients would contribute to avoid or at least reduce allotranfusion,hence ensuring the blood quantity and patient safety.