Induced Voltage and Alternating Current Loss in Superconducting Magnet System for SSTF

QL Wang,S Baang,CS Yoon,SB Kim,HK Park,MK Kim,YJ Kim,SI Lee,K Kim
DOI: https://doi.org/10.1109/77.920264
IF: 1.9489
2001-01-01
IEEE Transactions on Applied Superconductivity
Abstract:The induced voltage in the Samsung Superconducting Test Facility (SSTF) is analyzed according to the calculation of self-inductance and mutual inductance. The voltage induced by blip and compensating coils in the main coils is about 6.4 V. In order to charge the main coils, the power supply must provide the minimum voltage of 1.1 kV. The compensating coils have an influence on the field distribution. The compensating coils result in the decreasing center field about 2.67%. AC losses that include the coupling, hysteresis and eddy losses are calculated in the main, blip and compensating coils. It leads to the temperature rise of about 8 K in main coils