Magnetic Fluid Targeting Hyperthermia for Pancreatic Cancer in Mice
王露方,唐劲天,赵凌云,董坚
DOI: https://doi.org/10.3969/j.issn.1009-6604.2009.03.019
2009-01-01
Abstract:Objective To determine the heating ability of magnetic fluid in alternating magnetic field in vitro and its application to hyperthermia for pancreatic cancer in mice(MPC-83 cells).Methods Different concentrations of magnetic fluid were prepared in vitro,and heated for 30 min in an intermediate frequency alternating magnetic field.After the phagocytosis phenomenon was observed by transmission electron microscopy(TEM),MPC-83 cells were placed in an intermediate frequency alternating magnetic field with the temperature raised to 44 ℃.Apoptosis of the MPC-83 was quantitatively measured with flow cytometry,and the results were compared with that of smooth muscle cells(SMCs)obtained from rabbits.Results The temperature of magnetic fluid raised rapidly in the alternating magnetic field.The increase of the temperature was positively correlated to the concentration of magnetic fluid(n=5,r=0.937,P=0.019).TEM(×120 000)showed that the magnetic nanoparticles were phagocytosed by the MPC-83 cells;meanwhile flow cytometry revealed an apoptosis rate of(26.87±8.50)% in the MPC-83 cells,which was significantly higher than that in the SMC (18.45±3.28)%,n=3,t=1.601,P=0.185).Conclusions Magnetic fluid used for tumor therapy has a good heating ability in an alternating magnetic field in vitro and its temperature can be controlled by changing the concentration of the magnetic fluid.Magnetic nanoparticles can be simultaneously phagocytosed by MPC-83 cells,which is more sensitive to hyperthermia than normal cells.