Determination of Residual Dicyclanil in Animal Food by HPLC

WU Hai-xia,FENG Pei-sheng,ZHANG Su-xia,LI Lin-xia,CHENG Lin-li,CUI Yao-wen
2010-01-01
Abstract:A high-performance liquid chromatography method was developed for determination of dicyclanil in lamb and beef.The target compound was extracted from samples by acetonitrile,then was defatted by liquid-liquid extraction(LLE) with hexane,following cleaned up by a HLB SPE column.Finally,the prepared sample was determined by HPLC/UV at 270 nm.The calibration curve showed excellent linearity in the range of 20to 1000μg/L with correlation coefficient of 0.99.The mean average recoveries of dicyclanil ranged from 81.8%to 93.4%at spiked levels of 100to 1000μg/kg,with intra-assay(n =5)and inter-assay(n=3)coefficient of variation(CV)below 11.9%and 9.4%,respectively.The limit of detection(LOD) was 30.0μg/kg for lamb and 28.0μg/kg for beef.The limit of quantitation(LOQ)was 100.0μg/kg for lamb and 93.1μg/kg for beef.The results demonstrated that the method was simple,sensitive and accurate.It is applicable to detect dicyclanil in original food.
What problem does this paper attempt to address?