Abstract:Coagulation+iron-carbon microelectrolysis/H2O2+activated carbon process has been used for the combined treatment of high-concentration chemical cleaning wastewater.Its reaction mechanism and influencing factors are analyzed.The following optimal coagulation conditions are decided via experiments:pH is 8,PAC dosage 50 mg/L,PAM dosage 2 mg/L,and settling time 40 min.The optimal conditions for iron-carbon microelectrolysis/H2O2 are as follows:pH is 2,Fe+C total dosage 60 g/L,m(Fe)∶m(C) 1∶1,H2O2 dosage 4 mL/L,and reaction time 60 min.The optimal conditions for activated carbon adsorption are as follows:adsorption time is 120 min,pH 6,and activated carbon dosage 20 g/L.The results show that the COD removing rate can be above 98%,meeting the requirements of the first class of Integrated Wastewater Discharge Standard(GB 8978—1996) under the above optimal conditions.